code/sdk/application/wearable/fd230app/nativeui/bloodpressure/include/BPModel.h
code/sdk/application/wearable/fd230app/nativeui/bloodpressure/src/BPModel.cpp

  #include <stdint.h>
  #include <string>
  
 -namespace OHOS
 -{
 -    // 血氧检测状态
 -    enum class BPState
 -    {
 -        End = 0,
 -        Start,
 -    };
 -    enum class BPMain
 -    {
 -        NOT_TESTED = 0, // 未检测
 -        SUCCESS,        // 检测成功
 -        NOT_WORN,       // 未佩戴检测
 -        TIMEOUT,        // 检测超时
 -        HIGH_RESULT,    // 检测结果过高
 -        LOW_RESULT,     // 检测结果过低
 -        INVALID_DATA    // 无效数据
 -    };
 -    class BPModel
 -    {
 -    public:
 -        BPModel();
 -        ~BPModel();
 -        static BPModel *GetInstance();
 -
 -        void UpSPO2data(uint8_t spo2);
 -        uint16_t GetSPO2data();
 -        uint16_t GetShowSPO2data();
 -
 -        uint32_t GetCheckTime();
 -        void SetCheckTime(uint32_t time);
 -        void SetWearStatus(int32_t wear);
 -        void SetMain(BPMain result);
 -        BPMain GetMain();
 -
 -        void BP_Stop(void);
 -        void BP_Start(void);
 -        void BP_Save(void);
 -        void BP_Main(void);
 -
 -        void BP_Control(BPState state);
 -        void ClearDisplayData();
 -        void CleanAllData();
 -
 -         // 定时器管理
 -        void BP_StartTimer(uint32_t interval = 1000);
 -        void BP_StopTimer(void);
 -
 -
 -    private:
 -        uint16_t displayspo2;
 -        uint16_t currentspo2;
 -        uint32_t timestamp_ms;
 -        int32_t wear_;
 -
 -        bool sensorstate{false};
 -        bool startspo2{false};
 -
 -        uint16_t unwear_counter_;                           // 无效佩戴计数器
 -        uint16_t valid_counter_;                            // 有效数计数器
 -        uint16_t disvalid_counter_;                         // 无效数计数器
 -        BPMain bloodresult_ = BPMain::NOT_TESTED; // 检测结果
 -        bool initstatus;
 -    };
 -}
 +namespace OHOS {
 +// 血压检测状态
 +enum class BPState {
 +  End = 0,
 +  Start,
 +};
 +// 血压检测结果
 +enum class BPRESULT {
 +  NOT_TESTED = 0, // 未检测
 +  SUCCESS,        // 检测成功
 +  NOT_WORN,       // 未佩戴检测
 +  TIMEOUT,        // 检测超时
 +  HIGH_RESULT,    // 检测结果过高
 +  LOW_RESULT,     // 检测结果过低
 +  INVALID_DATA    // 无效数据
 +};
 +class BPModel {
 +public:
 +  BPModel();
 +  ~BPModel();
 +  static BPModel *GetInstance();
 +
 +  //获取当前时间年月日时分字符串
 +  std::string GetCurrentTimeStr();
++  // 定时器管理
++  void BP_StartTimer(uint32_t interval = 1000);
++  void BP_StopTimer(void);
 +
 +private:
 +};
 +} // namespace OHOS
  
  #endif
  #include "bloodpressure/include/BPModel.h"
  #include "bloodpressure/include/BPMainPresenter.h"
  
 -#include "DialModelSPO2.h"
 -#include "wearable_log.h"
  #include "heart_blood/health_service/health_service.h"
 -#include "custom_utils.h"
 +#include "wearable_log.h"
  
 -#include <cmsis_os2.h>
+ #include <cmsis_os.h>
++#include <cmsis_os2.h>
+ #include <service/graphic_service.h>
+ 
  extern "C" errcode_t uapi_get_timestamp_ms(uint32_t *tm);
  
 -#include "custom_utils.h"
 -#include "ppg_service.h"
 -#include "ConfigModel.h"
  #include "AppViewIDs.h"
 +#include "ConfigModel.h"
  #include "NativeAbility.h"
 -#include "battery_hal.h"
 -// #include "heart_blood/BloodCardView.h"
 -#include "MainViewSample.h"
  
 -#include <custom_save_runtime.h>
 +#include "battery_hal.h"
 +#include "custom_utils.h"
 +#include "ppg_service.h"
  
- 
  #define MAX_UNWARE_COUNT 10
  #define MAX_VALID_SPO2_COUNT 30
  #define MAX_DISVALID_SPO2_COUNT 100
 -namespace OHOS
 -{
 -    static osTimerId_t g_timer = nullptr;
 -    static int Time = 30;
 -
 -    /**
 -     * @brief Constructor for the BPModel class.
 -     */
 -    BPModel::BPModel()
 -    {
 -        // BPData *data = HealthService::GetInstance()->ReadBPData();
 -        // if (data)
 -        // {
 -        //     currentspo2 = data->SPO2;
 -        //     timestamp_ms = data->timestamp;
 -        //     // 更新表盘血氧数据
 -        //     DialModelSPO2::GetInstance()->UpdateSPO2(currentspo2);
 -        //     delete data;
 -        // }
 -        // else
 -        // {
 -            currentspo2 = 0;
 -            timestamp_ms = 0;
 -        // }
 -    }
 -    BPModel::~BPModel() {}
 -    BPModel *BPModel::GetInstance(void)
 -    {
 -        static BPModel instance;
 -        return &instance;
 -    }
 -    /* ---------------------------------- 状态检测 ---------------------------------- */
 -
 -    void BPModel::ClearDisplayData()
 -    {
 -      // currentspo2 = 0;
 -      // timestamp_ms = 0;
 -      // 不需要清空
 -    }
 -
 -    // 血氧监控
 -    void BPModel::BP_Control(BPState state)
 -    {
 -        // if (state == BPState::End && startspo2 == true)
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "startspo2 End");
 -        //     uint16_t md = PPG_SERVICE_CMD_TYPE_STOP_SPO2_TEST;
 -        //     send_ppg_cmd_msg(md);
 -        //     startspo2 = false;
 -
 -        //     uapi_save_runtime_log(RUNTIME_LOG_OXYGEN_MEASURE_END);
 -        // }
 -        // else if (state == BPState::Start && startspo2 == false)
 -        // {
 -        //     /*充电状态下不进行检测*/
 -        //     bool isCharging = get_charge_stat(); // 获取充电状态
 -        //     if (isCharging)
 -        //     {
 -        //         WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "充电不能检测");
 -        //         return;
 -        //     }
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "startspo2 Start");
 -        //     uint16_t md = PPG_SERVICE_CMD_TYPE_DO_SPO2_TEST;
 -        //     send_ppg_cmd_msg(md);
 -        //     startspo2 = true;
 -
 -        //     uapi_save_runtime_log(RUNTIME_LOG_OXYGEN_MEASURE);
 -        // }
 -    }
 -
 -    uint16_t BPModel::GetSPO2data()
 -    {
 -        return currentspo2;
 -    }
 -
 -    uint16_t BPModel::GetShowSPO2data()
 -    {
 -        return displayspo2;
 -    }
 -
 -    uint32_t BPModel::GetCheckTime()
 -    {
 -        return timestamp_ms;
 -    }
  
 -    void BPModel::SetCheckTime(uint32_t time)
 -    {
 -        timestamp_ms = time;
 -    }
 -    void BPModel::SetMain(BPMain result)
 -    {
 -        bloodresult_ = result;
 -    }
 -    BPMain BPModel::GetMain()
 -    {
 -        return bloodresult_;
 -    }
 -
 -    // 开始检测
 -    void BPModel::BP_Start()
 -    {
 -        // displayspo2 = 0;
 -        // SetMain(BPMain::NOT_TESTED); // 成功检测
 -        // // 进行初始化操作
 -        // if (!sensorstate)
 -        // {
 -        //     BP_Control(BPState::Start);
 -        //     sensorstate = true;
 -        // }
 -    }
 -
 -    // 结束检测
 -    void BPModel::BP_Stop()
 -    {
 -        // valid_counter_ = 0;
 -        // disvalid_counter_ = 0;
 -        // unwear_counter_ = 0;
 -
 -        // if (sensorstate)
 -        // {
 -        //     BP_Control(BPState::End);
 -        //     sensorstate = false;
 -        //     BP_Main(); // 处理结果
 -        // }
 -    }
 -
 -    // 保存检测数据
 -    void BPModel::BP_Save()
 -    {
 -//         uint32_t timestamp = BPMainPresenter::GetInstance()->GetCurrentTime();
 -//         SetCheckTime(timestamp);
 -// #if MSG_SAVE_TEST
 -//         BPData data;
 -//         data.SPO2 = currentspo2;
 -//         data.timestamp = timestamp_ms;
 -//         HealthService::GetInstance()->UpdateHealthData(data);
 -// #else
 -//         HealthService::GetInstance()->send_blood_save();
 -//     #endif
 -    }
 -
 -    // 显示检测结果// 显示检测结果
 -    void BPModel::BP_Main()
 -    {
 -        // uint16_t MiniBP = ConfigModel::GetInstance()->get_configData_int(ConfigModel::CONFIGMODEL_ITEM_OXYGEN_THRESHOLD_VALUE);
 -
 -        // // 检查当前血氧值并设置结果 需要检测成功
 -        // if(bloodresult_ == BPMain::SUCCESS){
 -        //     if (currentspo2 < MiniBP && currentspo2 != 0)
 -        //     {
 -        //         // 测量结果小于最小血氧值
 -        //         bloodresult_ = BPMain::LOW_RESULT;
 -        //         WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 低结果情况, currentspo2 = %d, MiniBP = %d", currentspo2, MiniBP);
 -        //     }
 -        // }
 -
 -        // // 根据结果进行处理
 -        // switch (bloodresult_)
 -        // {
 -        // case BPMain::SUCCESS:
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 成功");
 -        //     BP_Save();
 -        //     NativeAbility::GetInstance().Back(); // 成功
 -        //     break;
 -        // }
 -        // case BPMain::NOT_WORN: // 未佩戴状态
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 未佩戴状态");
 -        //     NativeAbility::GetInstance().ChangeSlice(VIEW_CHECK_ABNORMAL);
 -        //     break;
 -        // }
 -        // case BPMain::TIMEOUT: // 超时情况
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 超时情况");
 -        //     NativeAbility::GetInstance().ChangeSlice(VIEW_CHECK_ABNORMAL);
 -        //     break;
 -        // }
 -        // case BPMain::LOW_RESULT: // 低结果情况
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 低结果情况");
 -        //     HealthState healthState;
 -        //     healthState.checkType = BP_CHECK;
 -        //     healthState.resultStatus = LOW;
 -        //     healthState.checkMain = MiniBP;
 -        //     HealthService::GetInstance()->SetHealthCurrent(healthState);
 -        //     //保存异常数据
 -        //     BP_Save();
 -        //     NativeAbility::GetInstance().ChangeSlice(VIEW_CHECK_INVALID);
 -        //     break;
 -        // }
 -        // case BPMain::INVALID_DATA: // 无效数据情况
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 无效数据情况");
 -        //     NativeAbility::GetInstance().ChangeSlice(VIEW_CHECK_ABNORMAL);
 -        //     break;
 -        // }
 -        // default:
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 未知状态");
 -        //     break;
 -        // }
 -        // }
 -    }
 -    // 更新佩戴状态
 -    void BPModel::SetWearStatus(int32_t wear)
 -    {
 -        // // 设置佩戴状态
 -        // WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "BPModel Weartest::%d", wear);
 -        // //开启检测才对佩戴进行监听
 -        // if (sensorstate)
 -        // {
 -        //     // 计数更新
 -        //     if (wear_ != 1 && wear != 1)
 -        //     {
 -        //         unwear_counter_++; // 佩戴错误计时器计数
 -        //     }
 -        //     else
 -        //     {
 -        //         unwear_counter_ = 0; // 佩戴正常情况下清零计数器
 -        //     }
 -        //     wear_ = wear;
 -        //     // 检查是否达到了最大未佩戴计数限制
 -        //     if (unwear_counter_ >= MAX_UNWARE_COUNT)
 -        //     {
 -        //         WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 未佩戴计数最大 unwear_counter: %d", unwear_counter_);
 -        //         SetMain(BPMain::NOT_WORN);
 -        //         BP_Stop();
 -        //     }
 -        // }
 -    }
 +/*
 +----------------------------
 +收缩压:DBP
 +舒张压:SBP
 +血压:Blood Pressure(BP)
 +高血压:Hypertension
 +低血压:Hypotension
 +----------------------------
 +血压测量标准:
 +1、正常血压:收缩压(高压)<120 mmHg 且 舒张压(低压)<80 mmHg。
 +2、高血压:收缩压≥140 mmHg 或 舒张压≥90 mmHg。
 +3、低血压:收缩压<90 mmHg 且 舒张压<60 mmHg。
 +----------------------------
 +*/
 +namespace OHOS {
 +/**
 + * @brief Constructor for the BPModel class.
 + */
 +BPModel::BPModel() {}
 +BPModel::~BPModel() {}
 +BPModel *BPModel::GetInstance(void) {
 +  static BPModel instance;
 +  return &instance;
 +}
  
 -    // 更新SPO2数据
 -    void BPModel::UpSPO2data(uint8_t spo2)
 -    {
 -        // displayspo2 = spo2;
 +//获取当前时间戳字符串
 +std::string BPModel::GetCurrentTimeStr() {
 +  uint32_t timeStamp = 0;
  
 -        // // 处理有效与无效计数
 -        // if (displayspo2 != 0)
 -        // {
 -        //     currentspo2 = displayspo2; // 更新 currentspo2
 -        //     valid_counter_++;          // 增加有效计数器
 -        //     disvalid_counter_ = 0;     // 清空无效计数器
 -        // }
 -        // else
 -        // {
 -        //     disvalid_counter_++; // 增加无效计数器
 -        //     valid_counter_ = 0;  // 清零有效计数器
 -        // }
 +  if (uapi_get_timestamp_ms(&timeStamp) != ERRCODE_SUCC) {
 +    WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "Failed to get timestamp");
 +    return "----/--/-- /n --/--";
 +  }
  
 -        // // 检查无效计数器是否达标
 -        // if (disvalid_counter_ >= MAX_DISVALID_SPO2_COUNT)
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 无效数达标 disvalid_counter: %d", disvalid_counter_);
 -        //     SetMain(BPMain::INVALID_DATA); // 无效数达标
 -        //     BP_Stop();
 -        // }
 +  // 将时间戳转换为 time_t 类型
 +  time_t rawtime = static_cast<time_t>(timeStamp);
 +  struct tm *timeinfo = localtime(&rawtime);
  
 -        // // 检查有效计数器是否达标
 -        // if (valid_counter_ >= MAX_VALID_SPO2_COUNT)
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "检测结果: 成功 valid_counter: %d currentspo2: %d", valid_counter_, currentspo2);
 -        //     SetMain(BPMain::SUCCESS); // 成功检测
 -        //     BP_Stop();
 -        // }
 -    }
 +  if (timeinfo == NULL) {
 +    WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "Failed to convert time");
 +    return "----/--/-- /n --/--";
 +  }
  
 -    // 更新血氧数据
 -    void BPModel::CleanAllData(void)
 -    {
 -        WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "Nextday!");
 -        // if (MainViewSample::GetInstance() != nullptr && BPCardView::GetInstance() != nullptr)
 -        // {
 -        //     WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "更新主界面血氧卡片");
 -        //     BPCardView::GetInstance()->UpSPO2Text();
 -        // }
 -        if (BPMainView::GetInstance() != nullptr)
 -        {
 -            WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "更新测量血氧卡片");
 -           // BPMainView::GetInstance()->UpSPO2Text();
 -        }
 -    }
 -        /* -------------------------------------------------------------------------- */
 -    /*定时器到期时的处理*/
 -    static void BP_TimerCallbackProc(int data)
 -    {
 -        // 等待完成的定时器
 -        WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "BP_TimerCallbackProc,Time = %d", Time);
 -        if (Time < 0) // 如果校准超时30s,进入完成界面
 -        {
 -            BPModel::GetInstance()->BP_StopTimer();
 -            BPMainView::GetInstance()->ChangeView(BPUNDERCALIBRATIONVIEW,BPVALUEVIEW);
 -        }
 -        return;
 -    }
 +  // 格式化时间为字符串
 +  char buffer[20]; // 格式: YYYY-MM-DD HH:MM
 +  std::strftime(buffer, sizeof(buffer), "%Y-%m-%d  /n %H:%M", timeinfo);
  
 -    /*
 -     * @brief 回调函数
 -     */
 -    static void BP_TimerCallback(int data)
 -    {
 -        Time -= 1;
 -        GraphicService::GetInstance()->PostGraphicEvent(std::bind(BP_TimerCallbackProc, data));
 -    }
 +  return std::string(buffer);
 +}
+ 
 -    /*
 -     *  @brief 开启定时器函数
 -     *  @param interval 时间间隔,单位ms
 -     */
 -    void BPModel::BP_StartTimer(uint32_t interval)
 -    {
 -        WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "BPModel::BP_StartTimer");
 -        /* -------------------------- 1.检查定时器是否已经存在,如果存在则返回 ------------------------- */
 -        if (g_timer != nullptr)
 -        {
 -            WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "Timer already exists!!");
 -            return;
 -        }
+ 
 -        /* --------------------------------- 2.创建定时器 -------------------------------- */
 -        g_timer = osTimerNew((osTimerFunc_t)BP_TimerCallback, osTimerPeriodic, nullptr, nullptr);
 -        // 检查定时器创建是否成功
 -        if (g_timer == nullptr)
 -        {
 -            WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "Timer create failed!!");
 -            return;
 -        }
++///////////////////////////////////////////////////////////////////////////////////////
+ 
 -        /* ----------------------------- 3.将毫秒转换为系统时钟节拍数 ---------------------------- */
 -        int tick = osMs2Tick(interval);
++/*定时器到期时的处理*/
++static void BP_TimerCallbackProc(int data) {
++  // 等待完成的定时器
++  WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "BP_TimerCallbackProc,Time = %d",
++                Time);
++  if (Time < 0) // 如果校准超时30s,进入完成界面
++  {
++    BPModel::GetInstance()->BP_StopTimer();
++    BPMainView::GetInstance()->ChangeView(BPUNDERCALIBRATIONVIEW, BPVALUEVIEW);
++  }
++  return;
++}
+ 
 -        /* --------------------------------- 4.启动定时器 -------------------------------- */
 -        osStatus_t ret = osTimerStart(g_timer, tick);
 -        /* -------------------- 5.检查定时器启动是否成功,如果启动失败,删除定时器并置为 nullptr -------------------- */
 -        if (ret != osOK)
 -        {
 -            WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "osTimerDelete failed, ret = %lx!!", ret);
 -            if (g_timer != nullptr)
 -            {
 -                ret = osTimerDelete(g_timer);
 -            }
 -            g_timer = nullptr;
 -            return;
 -        }
 -    }
++/*
++ * @brief 回调函数
++ */
++static void BP_TimerCallback(int data) {
++  Time -= 1;
++  GraphicService::GetInstance()->PostGraphicEvent(
++      std::bind(BP_TimerCallbackProc, data));
++}
+ 
 -    /*
 -     * @brief 停止定时器
 -     */
 -    void BPModel::BP_StopTimer(void)
 -    {
 -        // 检查定时器是否存在
 -        if (g_timer != nullptr)
 -        {
 -            WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "BPModel::BP_StopTimer");
 -            osTimerStop(g_timer);
 -            // 删除定时器并置为 nullptr
 -            osStatus_t ret = osTimerDelete(g_timer);
 -            if (ret != osOK)
 -            {
 -                WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "osTimerDelete failed, ret = %lx!!", ret);
 -            }
 -            g_timer = nullptr;
 -            Time = 30;
 -        }
 -    }
++/*
++ *  @brief 开启定时器函数
++ *  @param interval 时间间隔,单位ms
++ */
++void BPModel::BP_StartTimer(uint32_t interval) {
++  WEARABLE_LOGD(WEARABLE_LOG_MODULE_APP, "BPModel::BP_StartTimer");
++  /* -------------------------- 1.检查定时器是否已经存在,如果存在则返回
++   * ------------------------- */
++  if (g_timer != nullptr) {
++    WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "Timer already exists!!");
++    return;
++  }
++
++  /* --------------------------------- 2.创建定时器
++   * -------------------------------- */
++  g_timer = osTimerNew((osTimerFunc_t)BP_TimerCallback, osTimerPeriodic,
++                       nullptr, nullptr);
++  // 检查定时器创建是否成功
++  if (g_timer == nullptr) {
++    WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "Timer create failed!!");
++    return;
++  }
++
++  /* ----------------------------- 3.将毫秒转换为系统时钟节拍数
++   * ---------------------------- */
++  int tick = osMs2Tick(interval);
++
++  /* --------------------------------- 4.启动定时器
++   * -------------------------------- */
++  osStatus_t ret = osTimerStart(g_timer, tick);
++  /* -------------------- 5.检查定时器启动是否成功,如果启动失败,删除定时器并置为
++   * nullptr -------------------- */
++  if (ret != osOK) {
++    WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "osTimerDelete failed, ret = %lx!!",
++                  ret);
++    if (g_timer != nullptr) {
++      ret = osTimerDelete(g_timer);
++    }
++    g_timer = nullptr;
++    return;
++  }
++}
++/*
++ * @brief 停止定时器
++ */
++void BPModel::BP_StopTimer(void) {
++  // 检查定时器是否存在
++  if (g_timer != nullptr) {
++    WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP, "BPModel::BP_StopTimer");
++    osTimerStop(g_timer);
++    // 删除定时器并置为 nullptr
++    osStatus_t ret = osTimerDelete(g_timer);
++    if (ret != osOK) {
++      WEARABLE_LOGE(WEARABLE_LOG_MODULE_APP,
++                    "osTimerDelete failed, ret = %lx!!", ret);
++    }
++    g_timer = nullptr;
++    Time = 30;
++  }
+ }
++
 +} // namespace OHOS