#define __MMI_HEALTH_MEASURE_TEMPERATURE_SUPPORT__
-#define __MMI_APP_QRCODE_MENU_SUPPORT__
+//#define __MMI_APP_QRCODE_MENU_SUPPORT__
#define __MMI_ZHSX_SUPPORT_NO_SIM_POWER_OFF__
#define __MMI_REMIND_take_off_SUPPORT__
-#define __MMI_BLOOD_PRESSURE_SUPPORT__
+#define __MMI_BP_CALIBRATE_SUPPORT__
//#define __MMI_PHONEBOOK_CALLLOG_IN_ONE_MENU__
// fzd debug-lab.xcloudtech.com:9000; fzd-api.xcloudtech.com:9000
// wulian-8.134.110.49:30346
// tongxin debug-tcptest.tx.kidxin.com:20500; tongxin-tcp.tx.kidxin.com:20500
-#define MMI_CUSTOMER_IP_ADDRESS "api.xcloudtech.com" // "8.134.110.49" // "lab.xcloudtech.com"
+#define MMI_CUSTOMER_IP_ADDRESS "api.xcloudtech.com" // "lab.xcloudtech.com"
-#define MMI_CUSTOMER_IP_PORT (9000) // (30346) // (9000)
+#define MMI_CUSTOMER_IP_PORT (9000) // (9000)
// fzd-"bZld0ALsZTt15tKEZhOlLPgbsO75BLTP"; wulian-"g3HOqJwHUhhA1myJnuur"
#define MMI_CUSTOMER_PROTOCOL_MD5_KEY "bZld0ALsZTt15tKEZhOlLPgbsO75BLTP" // "3JyCjsw4ryXKzjzudayY"
#define MMI_CUSTOMER_RING_VOLUME (10)
//backlight level
-#define MMI_CUSTOMER_BACKLIGHT_LEVEL (10)
+#define MMI_CUSTOMER_BACKLIGHT_LEVEL (8)
//backlight timeout
#define MMI_CUSTOMER_BACKLIGHT_TIMEOUT (15) // unit:s
-//pedometer body info
-#define MMI_CUSTOMER_BODY_HEIGHT (170)
-
-#define MMI_CUSTOMER_BODY_WEIGHT (60)
-
+//pedometer
#define MMI_CUSTOMER_STEP_GOAL (10000)
// dial pad
// sim unbind
#define MMI_CUSTOMER_SIM_UNBIND_SWITCH (MMI_WATCH_SWITCH_ON)
+// user profile
+#define MMI_CUSTOMER_USER_PROFILE_INDEX (MMI_USER_PROFILE_MODE_RING_VIB)
+
+// fall down
+#define MMI_CUSTOMER_FALL_DOWN_SWITCH (MMI_WATCH_SWITCH_OFF)
+// low battery
+#define MMI_CUSTOMER_LOW_BATTERY_SWITCH (MMI_WATCH_SWITCH_ON)
#endif
//drv
-#define DRV_PROJECT_Z5_Z11_2 1
+#define DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD 1
#define GPS_BATTERY_ALWAYS_ON 0
#endif
-#define USE_OEM_ZFB
-
#ifdef USE_OEM_ZFB
-#define USE_LV_WATCH_ALIPAY 1 // 1
+#define USE_LV_WATCH_ALIPAY 1
#else
#define USE_LV_WATCH_ALIPAY 0
#endif
#define __MMI_ZHSX_SUPPORT_SMS__
// project mmi
-#define MMI_PROJECT_Z5_K7
+#define MMI_PROJECT_Z5_DS_Z11XG_DTM_FZD
+#define MMI_PROJECT_Z5_DS_Z11_COMMON
#if 0 != USE_LV_WATCH_ALIPAY
//#define __MMI_ZHSX_SUPPORT_VIDEO_CALL_TONGXIN__
#define __MMI_WECHAT_SUPPORT__
+#define __MMI_WECHAT_RECEIVE_AUDIO_USE_MP3__
#define __MMI_MAIN_MENU_FOUR_GRID_STYLE__
#if 0 != USE_LV_WATCH_WEATHER
#define __MMI_WEATHER_MENU_SUPPORT__
+#define __MMI_WEATHER_MENU_NOT_DISPLAY_TEMPERATURE_RANGE__
#endif
#define __MMI_POWER_ON_OFF_NO_RING__
#define __MMI_KEY_BACK_RUN_PHONEBOOK_WHEN_IN_DIAL__
+#define __MMI_PAGE_MAIN_MENU_TTS_SUPPORT__
-#define __MMI_SEDENTARY_REMIND_SUPPORT__
+#define __MMI_USER_PROFILE_SUPPORT__
#define __MMI_NEW_SMS_SILENT_SUPPORT__
-
#define __MMI_REMIND_WAKE_UP_SUPPORT__
#define __MMI_REMIND_SLEEP_SUPPORT__
#define __MMI_REMIND_DRINK_SUPPORT__
-#define __MMI_USER_PROFILE_SUPPORT__
+#define __MMI_SEDENTARY_REMIND_SUPPORT__
#define __MMI_REMIND_take_off_SUPPORT__
-#define __MMI_BLOOD_PRESSURE_SUPPORT__
+#define __MMI_BP_CALIBRATE_SUPPORT__
#define __MMI_PHONEBOOK_CALLLOG_IN_ONE_MENU__
#define __MMI_SLEEP_FUNCTION_SUPPORT__
+#define __MMI_ZHSX_SUPPORT_AUTHENTICATE__
+
+#define __MMI_FZD_PROTOCOL_WITHOUT_PING_COMMAND_SUPPORT__
+
+#define __Default_system_alarm__
+
+#define __MMI_PEDOMETER_STEP_AND_GOAL_STYLE__
#endif
#define __MMI_REMIND_take_off_SUPPORT__
-#define __MMI_BLOOD_PRESSURE_SUPPORT__
+#define __MMI_BP_CALIBRATE_SUPPORT__
#define __MMI_SLEEP_FUNCTION_SUPPORT__
#define __MMI_REMIND_take_off_SUPPORT__
-#define __MMI_BLOOD_PRESSURE_SUPPORT__
+#define __MMI_BP_CALIBRATE_SUPPORT__
#define __MMI_SLEEP_FUNCTION_SUPPORT__
#define __MMI_REMIND_take_off_SUPPORT__
-#define __MMI_BLOOD_PRESSURE_SUPPORT__
+#define __MMI_BP_CALIBRATE_SUPPORT__
#define __MMI_PHONEBOOK_CALLLOG_IN_ONE_MENU__
static lcd_context g_lcd_ctx;
const static struct spi_write_t spi_init_watch[] = {
-#if DRV_PROJECT_Z5_Z11_2 || DRV_PROJECT_C55_DS_D11G_DT_HZCH
+#if DRV_PROJECT_Z5_Z11_2 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD
{ SPI_WRITE_CMD, 0x11, 0 },
{ SPI_WRITE_DELAY,120, 0 },
const static struct spi_info lcd_st7789v2_spi_info_watch = {
#if DRV_PROJECT_Z5_K6
4,//4线
-#elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_Z5_DS_Z12_COMMON || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_Z11_2
+#elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_Z5_DS_Z12_COMMON || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD || DRV_PROJECT_Z5_Z11_2
3,//3线
#else
3,//3线
#endif
1,
-#if DRV_PROJECT_Z5_K6 || DRV_PROJECT_Z5_Z11_2 || DRV_PROJECT_C55_DS_D11G_DT_HZCH
+#if DRV_PROJECT_Z5_K6 || DRV_PROJECT_Z5_Z11_2 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD
1,//1通道
#elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_Z5_DS_Z12_COMMON
2,//2通道
static void st7789v2_panel_invalid(uint32_t start_x,
uint32_t start_y, uint32_t end_x, uint32_t end_y)
{
-#if DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_Z11_2
+#if DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD || DRV_PROJECT_Z5_Z11_2
start_y += 20;
end_y += 20;
#endif
return 0;
err:
cplog_printf("panel detect by readid failed\n");
-#if DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_Z11_2
+#if DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD || DRV_PROJECT_Z5_Z11_2
return 0;
#else
return -1;
health_info->blood_low_value = s_health_info.blood_low_value;
health_info->spo2_value = s_health_info.spo2_value;
health_info->body_value = s_health_info.body_value;
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
+ health_info->bp_calibrate_high_value = s_health_info.bp_calibrate_high_value;
+ health_info->bp_calibrate_low_value = s_health_info.bp_calibrate_low_value;
+#endif
}
void mmi_health_info_set(nv_watch_health_info_t * health_info)
s_health_info.blood_low_value = health_info->blood_low_value;
s_health_info.spo2_value = health_info->spo2_value;
s_health_info.body_value = health_info->body_value;
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
+ s_health_info.bp_calibrate_high_value = health_info->bp_calibrate_high_value;
+ s_health_info.bp_calibrate_low_value = health_info->bp_calibrate_low_value;
+#endif
uint32_t nv_data_length = sizeof(nv_watch_health_info_t);
{
uint32_t roll_num = 0;
-#ifdef MMI_PROJECT_Z5_DS_Z12_COMMON
+#ifdef MMI_PROJECT_Z5_DS_Z12_COMMON || MMI_PROJECT_Z5_DS_Z11_COMMON
srand(Hal_Timer_Get_Counter());
roll_num = 1 + rand() % 25;
#endif
uint16_t spo2_value;
//float wrist_value;
float body_value;
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
+ uint16_t bp_calibrate_high_value;
+ uint16_t bp_calibrate_low_value;
+#endif
} __packed nv_watch_health_info_t;
#define NV_WATCH_SOS_NUMBER_MAX (3)
return NULL;
}
-// static VOID mmi_protocol_fzd_action_send_blood_Cb(void *para)
-// {
-// mmi_protocol_fzd_action_send_blood(blood_high_value,blood_low_value);
-
-// }
-
void health_heart_rate_display_update(void)
{
lv_heart_rate_obj_ext_t * ext = health_heart_rate_get_ext();
mmi_hsensor_blood_value_get(&blood_high_value,&blood_low_value);
sprintf(ext->blood_low_high, "%d / %d mmhg", blood_low_value,blood_high_value);
- // TIMER_ID t= Hal_Timer_Start(1000,mmi_protocol_fzd_action_send_blood_Cb,(void *)measure_type,false);
- mmi_protocol_fzd_action_send_blood(blood_high_value,blood_low_value);
-
+ mmi_protocol_action_send_blood(blood_high_value,blood_low_value);
lv_label_set_text(ext->label_value_blood, ext->blood_low_high);
lv_obj_align(ext->label_value_blood, ext->cont, LV_ALIGN_IN_TOP_MID, 0, HEART_LABEL_VALUE_Y+10);
void mmi_hsensor_blood_value_get(uint16_t * blood_high_value, uint16_t * blood_low_value)
{
- mmi_hsensor_measure_value_get(NULL, blood_high_value, blood_low_value, NULL);
+#ifdef __HEALTH_MEASURE_FAKE_DATA__
+ srand(Hal_Timer_Get_Counter());
+ * blood_high_value = 100 + rand() % 60;
+ * blood_low_value = 60 + rand() % 30;
+
+#else
+ uint16_t t_high_value = 0, t_low_value = 0;
+
+ mmi_hsensor_measure_value_get(NULL, &t_high_value, &t_low_value, NULL);
+
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
+ uint16_t bp_calibrate_high_value = 0, bp_calibrate_low_value = 0;
+ uint16_t t_value0 = 0, t_value1 = 0;
+
+ mmi_bp_calibrate_value_get(&bp_calibrate_high_value, &bp_calibrate_low_value);
+ t_value0 = bp_calibrate_high_value + (7 - (t_high_value % 15));
+ t_value1 = bp_calibrate_high_value + (7 - (t_low_value % 15));
+ t_high_value = t_value0;
+ t_low_value = t_value1;
+#endif
+
+ if(DEFAULT_BP_HIGH_VALUE_MAX < t_high_value)
+ t_high_value = DEFAULT_BP_HIGH_VALUE_MAX;
+ else if(DEFAULT_BP_HIGH_VALUE_MIN > t_high_value)
+ t_high_value = DEFAULT_BP_HIGH_VALUE_MIN;
+
+ if(DEFAULT_BP_LOW_VALUE_MAX < t_low_value)
+ t_low_value = DEFAULT_BP_LOW_VALUE_MAX;
+ else if(DEFAULT_BP_LOW_VALUE_MIN > t_low_value)
+ t_low_value = DEFAULT_BP_LOW_VALUE_MIN;
+
+ * blood_high_value = t_high_value;
+ * blood_low_value = t_low_value;
+
+ return true;
+#endif
}
void mmi_hsensor_spo2_value_get(uint16_t * spo2_value)
{
uint16_t t_high_value = 0, t_low_value = 0;
-#ifdef __HEALTH_MEASURE_FAKE_DATA__
- srand(Hal_Timer_Get_Counter());
- t_high_value = 120 + rand() % 100;
- t_low_value = 60 + rand() % 50;
-
-#else
mmi_hsensor_blood_value_get(&t_high_value, &t_low_value);
-#endif
-
- if(180 < t_high_value)
- t_high_value = 180;
- else if(120 > t_high_value)
- t_high_value = 120;
-
- if(110 < t_low_value)
- t_low_value = 120;
- else if(60 > t_low_value)
- t_low_value = 60;
* blood_high_value = t_high_value;
* blood_low_value = t_low_value;
#define MMI_HEART_RATE_VALUE_MIN (45)
+#define DEFAULT_BP_HIGH_VALUE_MAX (180)
+#define DEFAULT_BP_HIGH_VALUE_MIN (95)
+#define DEFAULT_BP_LOW_VALUE_MAX (95)
+#define DEFAULT_BP_LOW_VALUE_MIN (60)
+
+
typedef enum
{
#ifdef __MMI_NEW_SMS_SILENT_SUPPORT__
{ ICON_SETTING_NEW_SMS_SILENT, WATCH_TEXT_ID_NEW_SMS_SILENT, setting_new_sms_silent_create_event_cb },
#endif
-#ifdef __MMI_BLOOD_PRESSURE_SUPPORT__
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
{ BlOOD_PRESSURE_LIST_PNG, WATCH_TEXT_ID_Blood_pressure_calibration, setting_Blood_pressure_create_event_cb },
#endif
#ifdef __MMI_APP_QRCODE_MENU_SUPPORT__
lv_obj_set_width(info_label, LV_HOR_RES - 20);
lv_label_set_align(info_label, LV_LABEL_ALIGN_CENTER);
-#ifdef MMI_PROJECT_Z5_DS_Z12_COMMON
+#ifdef MMI_PROJECT_Z5_DS_Z12_COMMON || MMI_PROJECT_Z5_DS_Z11_COMMON
// snprintf(info_str, 96, "%s:Z5_Z12\n%s:%s_V1.0_Release_%s",
// (char *)lv_lang_get_text(WATCH_TEXT_ID_MODE),
// (char *)lv_lang_get_text(WATCH_TEXT_ID_VERSION_NUM),
#include "lv_watch.h"
#include "setting_blood_pressure_calibration.h"
-#ifdef __MMI_BLOOD_PRESSURE_SUPPORT__
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
static bool blood_state_falg;
TIMER_ID timer_blood_1=NULL;
+
+
+void mmi_bp_calibrate_value_get(uint16_t * high_value, uint16_t * low_value)
+{
+ uint16_t t_high_value = 0, t_low_value = 0;
+
+ nv_watch_health_info_t health_info = {0};
+ mmi_health_info_get(&health_info);
+
+ t_high_value = health_info.bp_calibrate_high_value;
+ if(0 == t_high_value)
+ t_high_value = DEFAULT_BP_CALIBRATION_HIGH_VALUE;
+
+ t_low_value = health_info.bp_calibrate_low_value;
+ if(0 == t_low_value)
+ t_low_value = DEFAULT_BP_CALIBRATION_LOW_VALUE;
+
+ * high_value = t_high_value;
+ * low_value = t_low_value;
+}
+
+void mmi_bp_calibrate_value_set(uint16_t high_value, uint16_t low_value)
+{
+ nv_watch_health_info_t health_info = {0};
+
+ mmi_health_info_get(&health_info);
+ health_info.bp_calibrate_high_value = high_value;
+ health_info.bp_calibrate_low_value = low_value;
+ mmi_health_info_set(&health_info);
+}
+
void * mmi_Blood_pressure_ext_get(void)
{
lv_obj_t * activity_obj = lv_watch_get_activity_obj(ACT_ID_WATCH_SETTING_COMMON);
lv_imgbtn_set_src(para, LV_BTN_STATE_RELEASED, BlOOD_PRESSURE_COFIREM_PNG_1);
lv_obj_t * label_save=lv_obj_get_child(para,NULL);
lv_label_set_text_id(label_save, WATCH_TEXT_ID_CALIBRATE_SUCCESS);
+
+ // save data
+ mmi_bp_calibrate_value_set(ext->high_blood_value, ext->low_blood_value);
}
//shutdown_confirm_btn_action(NULL,LV_EVENT_CLICKED);
}
switch(user_num)
{
case 0: // time decrease
- if(0 < ext->low_blood_value)
+ if(DEFAULT_BP_LOW_VALUE_MIN < ext->low_blood_value)
{
ext->low_blood_value -= 1;
}
break;
case 1: // time increase
- if(300 > ext->low_blood_value)
+ if(DEFAULT_BP_LOW_VALUE_MAX > ext->low_blood_value)
{
ext->low_blood_value += 1;
}
break;
case 2: // time decrease
- if(0 < ext->hight_blood_value)
+ if(DEFAULT_BP_HIGH_VALUE_MIN < ext->high_blood_value)
{
- ext->hight_blood_value -= 1;
+ ext->high_blood_value -= 1;
}
- sprintf(blood_vlue, "%d", ext->hight_blood_value);
- lv_label_set_text(ext->label_hight_blood, blood_vlue);
- lv_label_set_align(ext->label_hight_blood, LV_LABEL_ALIGN_CENTER);
- lv_obj_align(ext->label_hight_blood, lv_obj_get_parent(ext->label_hight_blood), LV_ALIGN_CENTER, 0, 0);
+ sprintf(blood_vlue, "%d", ext->high_blood_value);
+ lv_label_set_text(ext->label_high_blood, blood_vlue);
+ lv_label_set_align(ext->label_high_blood, LV_LABEL_ALIGN_CENTER);
+ lv_obj_align(ext->label_high_blood, lv_obj_get_parent(ext->label_high_blood), LV_ALIGN_CENTER, 0, 0);
break;
case 3: // time increase
- if(300 > ext->hight_blood_value)
+ if(DEFAULT_BP_HIGH_VALUE_MAX > ext->high_blood_value)
{
- ext->hight_blood_value += 1;
+ ext->high_blood_value += 1;
}
- sprintf(blood_vlue, "%d", ext->hight_blood_value);
- lv_label_set_text(ext->label_hight_blood, blood_vlue);
- lv_label_set_align(ext->label_hight_blood, LV_LABEL_ALIGN_CENTER);
- lv_obj_align(ext->label_hight_blood, lv_obj_get_parent(ext->label_hight_blood), LV_ALIGN_CENTER, 0, 0);
+ sprintf(blood_vlue, "%d", ext->high_blood_value);
+ lv_label_set_text(ext->label_high_blood, blood_vlue);
+ lv_label_set_align(ext->label_high_blood, LV_LABEL_ALIGN_CENTER);
+ lv_obj_align(ext->label_high_blood, lv_obj_get_parent(ext->label_high_blood), LV_ALIGN_CENTER, 0, 0);
break;
- case 4: // time increase
+ case 4: //
lv_obj_add_state(obj,LV_STATE_DISABLED);
lv_imgbtn_set_src(obj, LV_BTN_STATE_RELEASED, BlOOD_PRESSURE_COFIREM_PNG_2);
// if(timer_blood_1!=NULL)
if(NULL == ext)
return NULL;
ext->blood_state_falg=true;
- uint16_t blood_high_value = 0;
- uint16_t blood_low_value = 0;
-
- mmi_hsensor_blood_value_get(&blood_high_value,&blood_low_value);
-
- ext->low_blood_value = blood_low_value;
- ext->hight_blood_value = blood_high_value;
-
-
+ mmi_bp_calibrate_value_get(&(ext->high_blood_value), &(ext->low_blood_value));
lv_obj_t * label_0 = lv_label_create(obj, NULL);
lv_obj_add_style(label_0, LV_LABEL_PART_MAIN, &lv_watch_font26);
lv_label_set_align(hight_blood, LV_LABEL_ALIGN_CENTER);
lv_obj_set_click(hight_blood, false);
char blood_str_1[8] = {0};
- sprintf(blood_str_1, "%d", ext->hight_blood_value);
+ sprintf(blood_str_1, "%d", ext->high_blood_value);
lv_label_set_text(hight_blood, blood_str_1);
lv_obj_align(hight_blood, NULL, LV_ALIGN_CENTER, 0, 0);
- ext->label_hight_blood = hight_blood;
+ ext->label_high_blood = hight_blood;
//
lv_obj_t * btn_save = lv_imgbtn_create(obj, NULL);
#endif
+#define DEFAULT_BP_CALIBRATION_HIGH_VALUE (113)
+#define DEFAULT_BP_CALIBRATION_LOW_VALUE (76)
typedef struct
/*New data for this type */
bool blood_state_falg;
uint16_t low_blood_value;
- uint16_t hight_blood_value;
+ uint16_t high_blood_value;
lv_obj_t * label_low_blood;
- lv_obj_t * label_hight_blood
+ lv_obj_t * label_high_blood;
} lv_Blood_pressure_obj_ext_t;
void setting_Blood_pressure_create_event_cb(lv_obj_t * btn, lv_event_t event);
-
+void mmi_bp_calibrate_value_get(uint16_t * high_value, uint16_t * low_value);
#ifdef __cplusplus
lv_obj_t * label = lv_label_create(status_ext->network_status_cont, NULL);
lv_obj_add_style(label, LV_LABEL_PART_MAIN, &lv_watch_font20);
if(MMI_MODEM_PLMN_RAT_LTE == rat) {
- #ifdef MMI_PROJECT_Z5_DS_Z12_COMMON
+ #ifdef MMI_PROJECT_Z5_DS_Z12_COMMON || MMI_PROJECT_Z5_DS_Z11_COMMON
lv_label_set_text(label, "5G");
#else
lv_label_set_text(label, "4G");
#define ANIM_HENGAI_BP_WAITTING "R:/gif/custom_function/ANIM_HENGAI_BP_WAITTING.gif"
#endif
-#ifdef __MMI_BLOOD_PRESSURE_SUPPORT__
+#ifdef __MMI_BP_CALIBRATE_SUPPORT__
#define BlOOD_PRESSURE_LIST_PNG "R:/png/setting_blood_pressure/IMAGE_SET_BP_CALIBRATION.png"
#define BlOOD_PRESSURE_strip_PNG "R:/png/setting_blood_pressure/IMAGE_BP_CALIBRATION_VALUE_BG.png"
#define BlOOD_PRESSURE_strip_PNG_1 "R:/png/setting_blood_pressure/IMAGE_BP_CALIBRATION_VALUE_BG_lift.png"
#define BlOOD_PRESSURE_strip_PNG_2 "R:/png/setting_blood_pressure/IMAGE_BP_CALIBRATION_VALUE_BG_right.png"
#define BlOOD_PRESSURE_COFIREM_PNG_1 "R:/png/setting_blood_pressure/IMAGE_BP_CALIBRATION_BUTTON_NORMAL.png"
#define BlOOD_PRESSURE_COFIREM_PNG_2 "R:/png/setting_blood_pressure/IMAGE_BP_CALIBRATION_BUTTON_PROCESS.png"
-
-
-
#endif
#endif
MFP_EOC
};
#endif
-#if DRV_PROJECT_Z5_K7 || USE_LCD_PANEL_GC9A01_SPI_WATCH|| DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_Z11_2
+#if DRV_PROJECT_Z5_K7 || USE_LCD_PANEL_GC9A01_SPI_WATCH|| DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD || DRV_PROJECT_Z5_Z11_2
static uint32_t lcd_poc_mfp_spi_3_2_cfgs[] = {
MFP_REG(GPIO_20) | MFP_AF2 | MFP_PULL_HIGH | MFP_SLEEP_DIR | MFP_DRIVE_MEDIUM | MFP_LPM_EDGE_NONE, /* SPI_DCLK */
MFP_REG(GPIO_21) | MFP_AF3 | MFP_PULL_HIGH | MFP_SLEEP_DIR | MFP_DRIVE_MEDIUM | MFP_LPM_EDGE_NONE, /* SPI_CS1 */
.mfp = (uint32_t *)lcd_poc_mfp_spi_4_1_cfgs,
.clk = 312000, /* 104000 */
};
-#elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_Z11_2
+#elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD || DRV_PROJECT_Z5_Z11_2
static struct lcd_info_t st7789v2_lcd_spi_3_2_info =
{
.mfp = (uint32_t *)lcd_poc_mfp_spi_3_2_cfgs,
#if USE_LCD_PANEL_ST7789V2_SPI_WATCH
#if DRV_PROJECT_Z5_K6
&st7789v2_lcd_spi_4_1_info,
- #elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_Z5_DS_Z12_COMMON || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_Z11_2
+ #elif DRV_PROJECT_Z5_K7 || DRV_PROJECT_Z5_HA_K7 || DRV_PROJECT_Z5_DS_Z12_COMMON || DRV_PROJECT_C55_DS_D11G_DT_HZCH || DRV_PROJECT_Z5_DS_Z11XG_DTM_FZD || DRV_PROJECT_Z5_Z11_2
&st7789v2_lcd_spi_3_2_info,
#endif
#endif